020 3600 1405 admin@frawizard.co.uk
  • Facebook
  • X
  • Instagram
  • RSS
  • Facebook
  • X
  • Instagram
  • RSS
fra-wizard.co.uk
  • Home
  • Services
    • Fire Risk Assessments
    • Fire Door Compliance
    • Fire Safety Policies
    • Health and Safety
    • Courses
    • Evacuation Plan Tool
  • Pricing
  • Blog
  • Support
  • Contact
  • Sign Up
Select Page

How can we help?

Type your search query into the search bar

Popular Searches evacuation plansfire policiesfire risk assessments

Using FRA Wizard

  • About User Credits
  • Audit Requests
  • Creating a Fire Risk Assessment (FRA)
  • Fire Door Compliance
  • Fire Safety Policies
  • Getting Started
  • Health and Safety Policies
  • How to Redeem Licence Keys
  • Learning Hub
  • My Account Section
  • Occupancy Calculator
  • Reports

Fire Risk Assessments

  • Fire Doors
  • Fire Precautions
  • Fire Sources
  • Fire Wardens
  • Fuel Sources
  • General Information
  • Maintenance
  • Means of Escape
  • People at Risk
  • Policies and Procedures
  • Property Information
  • Training

Emergency Lighting

  • Emergency Lighting Systems
  • Emergency Lighting Test Checklist
  • Guide to Conducting an EML Test
  • Regulatory Requirements for EML
  • The Role of EML in Fire Safety Plans
  • Understanding your EML Test

Fire Policies

  • Fire Policies in the Workplace
  • Implementation and Communication
  • Introduction to Fire Safety Policies
  • Key Components of a Fire Safety Policy
  • Legal Requirements

Heath & Safety

  • Chemicals and Hazardous Substances
  • Health and Safety Auditing
  • Health and Safety Regulations
  • Incident Reporting Procedures
  • Stress and Mental Health Support
  • Workplace Health and Safety

Fire Extinguishers

  • Extinguisher Symbols & Signage
  • Fire Extinguisher Regulations
  • Fire Extinguisher Reports
  • Fire Extinguisher Testing
  • WC and WM Fire Extinguishers

Fire Safety Information

  • Conducting a Fire Risk Assessment
  • Fire Safety Audits: Importance and Best Practices
  • Fire Safety Training: Essential Components and Best Practices
  • Fire Suppression Systems
  • Guide to Checking Escape Routes
  • Identifying and Collecting Images
  • Testing Fire Alarm Call Points
  • What are AOV Roof Vents?

Evacuation Plans

  • Common Mistakes to Avoid in Evacuation Planning
  • Conducting Fire Drills: Best Practices
  • Creating a Culture of Fire Safety Awareness
  • Emergency Communication Systems in Evacuation Plans
  • Evacuation Plan Requirements under the RRFSO
  • Evacuation Plans for People with Disabilities
  • Fire Safety Audits: Importance and Best Practices
  • Fire Safety Compliance: Understanding Your Legal Obligations
  • How to Develop an Effective Evacuation Plan
  • Reviewing and Updating Your Evacuation Plan
  • Role of Fire Wardens in Evacuation Plans
  • Technological Advances in Evacuation Planning
  • What is an Evacuation Plan?

Technical Support

  • How to Report a Problem
  • Troubleshooting Common Issues

Supporting Documents

  • 3 Floor Levels Grade A LD2 Alarm Systems
  • Alternative Escape Routes
  • Aluminium Cladding
  • Block and Beam Flooring
  • Carbon Monoxide Alarms
  • Carbon Monoxide: Boiler Rooms
  • Carbon monoxide: Commercial Kitchens
  • Carbon Monoxide: Open Fire Places
  • Cob Walls
  • Combustible Materials and Ignition Sources
  • Completing a Fire Safety Log Book
  • Concrete Buildings
  • Concrete Flooring
  • Construction Site Fire Hazards
  • COSHH Storing Chemicals
  • COSHH Storing Flammable Chemicals
  • Displaying a Fire Notice
  • Electric Fuse Board Cupboards
  • Electric Fuse Boards
  • Emergency Lighting Guide
  • Emergency Lighting: High Risk Task Areas
  • Emergency Lighting: Offices
  • Emergency Lighting: Three Storey Buildings
  • Evacuation Assembly Points
  • Evacuation Plan Example
  • Fire Alarm Call Points
  • Fire Alarm Sounders
  • Fire Alarms for Restaurants
  • Fire Alarms Grade A-C
  • Fire Alarms Grade D
  • Fire Alarms Grade F
  • Fire Alarms Office / Communal
  • Fire and Smoke Curtains
  • Fire Blankets
  • Fire Door Compliance Guide
  • Fire Door Compliance Landlord / HMO
  • Fire Door Compliance: Flat Entrance Doors
  • Fire Door Compliance: Office Doors
  • Fire Door Compliance: Offices
  • Fire Door Signage
  • Fire Door Signage: Electrical Cupboards
  • Fire Extinguisher Guide
  • Fire Fighting Equipment
  • Fire Glass & Glazing
  • Fire Rated Ductwork/Dampers
  • Fire Safety Document Boxes
  • Fire Safety Signage
  • Fire Supression Systems
  • Fire Wardens
  • Flat Bitumen Felt Roofing
  • Flat Fibreglass Roofing
  • Gas and Electric Fire Suppression Systems
  • Glass Curtain Wall Systems
  • Heat Detectors
  • In-House User Checks
  • Internal Fire Action Sign
  • Internal Timber Stud Framed Walls
  • Intumecsent Pipe Collars
  • Kitchen Extraction Hoods/Fans
  • Kitchen Fire Suppression Systems
  • Means of Escape
  • Metal Fire Doors
  • Metal Stud Framed Walls
  • Pitched Slate Roofing
  • Pre-Cast Concrete Flooring
  • Prefabricated / System Built Properties
  • Regular In-House Call Point Testing
  • Safe Storage of Flammable Materials
  • Sedum Roofing
  • Servicing Air Conditioning Units
  • Servicing Compressors/Machinery
  • Sheet Copper Roofing
  • Sheet Metal Roofing
  • Smoke Detectors
  • Smoke Detectors Residential, 1-2 Storeys
  • Smoking in Allocated Outdoor Areas
  • Solid Brick and Cavity Walls
  • Sprinkler Systems
  • Staff Fire Training
  • Storing Battery Powered E-Vehicles Safely
  • Thatched Roofing
  • The Responsible Person
  • Tiled Roofing
  • Timber Frames
  • Timber Joist Flooring
View Categories
  • Home
  • Docs
  • Emergency Lighting
  • Emergency Lighting Test Checklist

Emergency Lighting Test Checklist

Before proceeding with the detailed steps of emergency lighting testing, it is essential to ensure that every aspect of your system is thoroughly checked and documented. The following checklist will guide you through the necessary checks, ensuring that your emergency lighting system is compliant, functional, and safe.

This section covers everything from system plans and design to the quality of components and final acceptance. By following this checklist, you’ll be able to identify any issues and take the necessary actions to maintain a reliable emergency lighting system.

System Plans and Design #

  • Are the plans of the system available and correct?
  • Is the system designed for the correct mode of operation category?
  • Is the system designed for the correct emergency duration period?

Documentation #

  • Is a completion certificate available with photometric design data?
  • Is a test log book available, and are entries up to date?

Design Check #

  • Are the correct areas of the premises covered to meet the risk assessment?
  • Are all hazards identified by the risk assessment covered?
  • Are there luminaires cited at the “points of emphasis”?
  • Is the spacing between luminaires compliant with authenticated spacing or design data?
  • Are estimates attached and acceptable if authenticated spacing data is unavailable for existing installations?
  • Are the emergency exit signs and escape route direction signs correct, and are other safety signs to be illuminated under emergency conditions identified?

Luminaires and Illumination #

  • Do all non-maintained luminaires operate on local final circuit failure?
  • Is there illumination from at least two luminaires in each section of the escape route?
  • Are luminaires at least 2m above the floor and avoiding smoke reservoirs?
  • Can additional luminaires cover toilets, lifts, plant rooms, etc.?

Quality of System Components and Installation #

  • Do the luminaires conform to BS EN 60598-2-22?
  • Do any converted luminaires conform to BS EN 60598-2-22?
  • Do luminaires have a suitable degree of protection for their location?
  • Does the installation conform to the good practice defined in BS 7671?
  • For centrally powered systems, is the wiring fire-resistant?
  • Are any plugs or sockets protected against unauthorized use?
  • If a central power supply unit is used, does it conform to BS EN 50171?

Test Facilities #

  • Are the test facilities suitable for testing function and duration?
  • Are the test facilities safe to operate and do not isolate a required service?
  • Are the test facilities marked with their function?
  • If an automatic test system is installed, does it conform to BS EN 62034?
  • Is the responsible person trained and able to operate the test facilities and record the test results correctly?

Final Acceptance #

  • Does the system operate correctly when tested?
  • Has adequate documentation been provided to the user?
  • Is the user aware of actions they should take in case of a test failure?

This simplified checklist ensures you cover all essential aspects during your emergency lighting system testing.

Getting Started, User Onboarding
Did this help?
Share This Article :
  • Facebook
  • X
  • LinkedIn
  • Pinterest
Still stuck? How can we help?

How can we help?

Updated on 24/07/2024
Table of Contents
  • System Plans and Design
  • Documentation
  • Design Check
  • Luminaires and Illumination
  • Quality of System Components and Installation
  • Test Facilities
  • Final Acceptance
  • Privacy Policy
  • Terms and Conditions
© 2024 FRA Wizard | All Rights Reserved